For most IT candidates, obtaining an authoritative certification will let your resume shine and make great difference in your work. Especially when you get a high CEM passing score in test, it means that you have capability to handle with professional issue of technology and you are quite qualified for IT work. Certified Energy Manager (CEM) pass exam will bring more fortune to you. But you know good thing always need time and energy. As the data of certificate center shown, Certified Energy Manager (CEM) pass rate tend to low in recent years for its high-quality and difficulty. So how to prepare Certified Energy Manager (CEM) pass review is very important for most people who are desire to pass test quickly. I think PassReview will be best choice for your Certified Energy Manager (CEM) pass exam. You don't need to spend much time and energy in Certified Energy Manager (CEM) exam review, just make most of your spare time to practice Certified Energy Manager (CEM) review dumps, if you insist, it will easy for you to get high Certified Energy Manager (CEM) passing score.
PassReview is a website focused on the study of Certified Energy Manager (CEM) pass exam for many years and equipped with a team of professional IT workers who are specialized in the Certified Energy Manager (CEM) pass review. They create the CEM review dumps based on the real questions and check the updating of CEM exam review everyday to ensure the high of Certified Energy Manager (CEM) pass rate. You just need to prepare Certified Energy Manager (CEM) pass review and practice Certified Energy Manager (CEM) review dumps at your convenience when you bought dumps from us. If you do these well, Certified Energy Manager (CEM) pass exam is just a piece of cake.
Ensure you a high Certified Energy Manager (CEM) pass rate
Apart from the profession of our Certified Energy Manager (CEM) exam review, our CEM pass rate is high up to 89%. Lots of our returned customers give a feedback that our CEM review dumps are 85% similarity to the real test. Besides, more than 100000+ candidates participate in our website because of the accuracy and valid of our Certified Energy Manager (CEM) exam review. You can absolutely rest assured of the accuracy and valid of our Certified Energy Manager (CEM) pass review.
Online test engine version
Online test engine enjoys great popularity among IT workers because it bring you feel the atmosphere of the actual test and can support any electronic equipment. It means you can prepare the Certified Energy Manager (CEM) exam review anywhere and anytime. You can make full use of your spare time to practice CEM review dumps. Online version will also improve your Certified Energy Manager (CEM) passing score if you do it well.
We adhere to concept of No Help, Full Refund. If you failed the test with our CEM exam review we will full refund you. And you have right to free update of CEM review dumps one-year. There are 24/7 customer assisting support you, please feel free to contact us.
Instant Download CEM Exam Braindumps: Upon successful payment, Our systems will automatically send the product you have purchased to your mailbox by email. (If not received within 12 hours, please contact us. Note: don't forget to check your spam.)
AEE CEM Exam Syllabus Topics:
| Section | Weight | Objectives |
|---|---|---|
| Energy Accounting and Economics | 10-15% | - Life cycle cost analysis (LCCA) - Financial analysis techniques (ROI, NPV, IRR) - Utility rate structures and tariffs - Energy cost accounting and allocation - Energy price forecasting |
| Energy Auditing | 15-20% | - Data collection and analysis - Baseline establishment - Types of energy audits (preliminary, detailed, investment-grade) - Metering and measurement equipment - Audit procedures and methodologies - Audit report writing |
| Heating, Ventilating, and Air Conditioning (HVAC) | 12-18% | - Psychrometrics - Controls and optimization - Load calculations - Equipment efficiency ratings - Indoor air quality - HVAC system types and components - Heat transfer principles |
| Building Envelope | 8-12% | - Daylighting and shading - Air leakage and infiltration - Insulation types and R-values - Thermal envelope analysis - Windows and glazing systems |
| Facilities Management | 8-12% | - Preventive maintenance programs - Operations and maintenance best practices - Commissioning and re-commissioning - Building automation systems (BAS) - Monitoring and targeting (M&T) |
| Environmental and Regulatory Compliance | 5-10% | - Carbon footprint calculation - EPA regulations (Clean Air Act, Clean Water Act) - Sustainability reporting - Energy reporting requirements - Green building standards (LEED, ENERGY STAR) |
| Energy Project Implementation | 8-12% | - Performance contracting (ESPC) - Project risk management - Project financing models - Energy service companies (ESCOs) - Measurement and verification (M&V) - Implementation strategies |
| Renewable Energy Technologies | 8-12% | - Geothermal systems - Biomass and bioenergy - Wind energy systems - Solar thermal systems - Energy storage technologies - Solar photovoltaic systems |
| Electric Power Systems | 10-15% | - Motors and drives - Power distribution systems - Harmonics and power quality - Standby power systems - Lighting systems and controls - Power factor correction |
AEE Certified Energy Manager (CEM) Sample Questions:
Question 1
You can buy air compressor A for $15,000 or air compressor B for $6,000. Compressor A will cost $10,000 per year to operate. Compressor B will cost $11,500 per year to operate. If both air compressors have a 10- year life and your required return on investment is 12%, which air compressor has the lowest total life-cycle cost?
A. Compressor A
B. Both air compressors have the same life-cycle cost
C. Compressor B
Question 2
For general indoor residential lighting applications, which light source can provide the most appropriate illumination with the highest efficacy?
A. Low-pressure sodium (LPS)
B. Mercury vapor (MV)
C. Incandescent
D. Compact fluorescent (CFL)
E. Light-emitting diode (LED)
Question 3
A cooling tower delivers water to a chilled-water plant at 21°C. The outside ambient air conditions are 19°C dry bulb, 50% relative humidity. Using the psychrometric chart, what is the approach temperature of the cooling tower outlet water temperature to the ambient air wet-bulb temperature?
SELECT THE CORRECT ANSWER
A. 8°C
B. 6°C
C. 10°C
D. 4°C
Question 4
What is the Energy Use index (EUl) for a 4,000 m2 building that uses the following amounts of energy each year?
A. 1,612,000 kJ/m²-yr
B. 855,250 kJ/m²-yr
C. 403,311 kJ/m²-yr
D. 625,600 kJ/m²-yr
E. 3,220,800 kg/m²-yr
Question 5
In a performance contract, which group has the greatest investment risk?
A. Risk is shared by the terms in the performance contract
B. The company installing the energy project
C. The equipment manufacturer
D. The energy-service company
Solutions:
| Question 1 Answer: C | Question 2 Answer: E | Question 3 Answer: A | Question 4 Answer: D | Question 5 Answer: D |