[Q14-Q33] 2023 Valid NS0-593 Dumps for Helping Passing Network Appliance Exam!

Share

2023 Valid NS0-593 Dumps for Helping Passing Network Appliance Exam!

Download Free Network Appliance NS0-593 Exam Questions & Answer 


Network Appliance NS0-593 exam is designed for IT professionals who wish to prove their expertise in supporting NetApp ONTAP storage solutions. NS0-593 exam is a specialist-level certification that focuses on assessing the candidate's skills related to supporting NetApp storage systems. NS0-593 exam tests the candidate's knowledge and skills in troubleshooting, configuring, and maintaining NetApp ONTAP storage solutions.

 

NEW QUESTION # 14
You want to assign storage access to an NVMe protocol host.
Which three objects must beconfigured to accomplish this task? (Choose three.)

  • A. an NVMe LIF
  • B. the NVMe subsystem
  • C. an NVMe LUN
  • D. the NVMe broadcast domain
  • E. the NVMe namespace

Answer: A,B,D


NEW QUESTION # 15
You have a NetApp ONTAP cluster consisting of four NetApp FAS8200 controllers with two NetApp
CN1610 cluster switches running ONIAP 9.8 software. You are receiving several alert messages stating that
the cluster network has degraded. After troubleshooting, you determine that the errors are being generated
fromNode 2, interface e0b.
In this scenario, what should you do first to solve this problem?

  • A. Replace the motherboard on Node 2.
  • B. Replace both NetApp CN1610 switches.
  • C. Replace the Twinax cable between Node 2, Interface e0b. and the NetApp CN1610 switch.
  • D. Replace the NetApp CN1610 switch that connects to Node 2, interface e0b.

Answer: A


NEW QUESTION # 16
Recently, a CIFS SVM was deployed and is working. The customer wants to use the Dynamic DNS(DDNS)
capability available in NetApp ONTAP to easily advertise both data UFs to their clients. Currently. DNS is
only responding with one data LIF. DDNS is enabled on the domain controllers.

Referring to the exhibit, which two actions should be performed to enable DDNS updates to work? (Choose
two.)

  • A. Enable the -is-enabledparameter for the SVM DDNS services
  • B. Enable the -use-secure parameter for the SVM DDNS services.
  • C. Disable the -vserver-fqdn parameter for the SVM DDNS services.
  • D. Remove the NFS protocol from the cifs_01 data LIF.

Answer: A,C


NEW QUESTION # 17
A user mentions that their home drive, that Is an export within a volume, is no longer allowing them to save
files. The drive reports that it Is full, even though It shows that minimal data is written to it.
Which statement would explain this behavior?

  • A. Other users wrote to this user's home drive.
  • B. The client system needs to remount the export to show the proper space.
  • C. The mount is stale and uses a cached version of the volume.
  • D. Other files within the volume are also owned by the user, exceeding the user quota.

Answer: D


NEW QUESTION # 18
You receive the "Unable to connect to the management gateway server"error when trying to connect to a node
management IP.
In this situation, how do you determine whether core dumps are generated for the mgwd user space process?

  • A. Log in to the nodeshell using the node console and collect the core dumps from the nodeshell.
  • B. Log in to the service processor and collect the core dumps from the service processor.
  • C. Log in to the clustershell using the node console and collect the core dumps from the clustershell.
  • D. Log in to the systemshell and collect core dumps from thesystemshell.

Answer: B


NEW QUESTION # 19
After users start reporting the Inability to create new flies in a CIFS share, you find EMS events for
wafl.dir.size.max logged for the volume of the SVM to which the share points.
In this scenario, which action should you take to solve this issue?

  • A. Move the volume to a different aggregate.
  • B. Increase the maximum numberof files for the volume.
  • C. Increase the maximum directory size for the volume.
  • D. Delete unneeded files from the directory.

Answer: B


NEW QUESTION # 20
You created a new NetApp ONTAP FlexGroup volume spanning six nodes and 12 aggregates with a total size
of 4 TB. You added millions of files to the FlexGroup volume with a flat directory structure totaling 2 TB, and
you receive anout of apace error message on your host.
What would cause this error?

  • A. The inode limit is exceeded in the ONTAP software.
  • B. All constituent volumes are full.
  • C. The maxdirsize Is exceeded in the ONTAP software.
  • D. The maximum number of volume constituents has been reached in the ONTAP software.

Answer: A


NEW QUESTION # 21
You ate connecting a Windows Server 2019 hostto ISCSI LUNs on a 4-node AFF A250 cluster running
NetApp ONIAP 9.8 software. The host is unable to connect to the target interface, and the ONTAP event log
has the message shown below.
ISCSI: network interface identifier disabled for use; incoming connection discarded
In this scenario, what is the cause of this connection issue?

  • A. CHAP isnot configured correctly for the specified initiator.
  • B. The WWPN was not added to the initiator group.
  • C. The iSCSI service is not enabled on the interface.
  • D. iSNS is not enabled on the storage virtual machine.

Answer: B


NEW QUESTION # 22
A storage administrator reports that a monitoring toot is reporting that the storage controller reads between
90% to 93% CPU use. You run the sysstat -m command against thenode in question.

Referring to the exhibit, which statement is correct?

  • A. The customer should be advised to exclude certain workflows to reduce use.
  • B. The CPU Is not a first-order monitoring metric for ONTAP.
  • C. High network exempt use could be a problem.
  • D. You should immediately investigate further bygathering perfstat data and opening a support case.

Answer: D


NEW QUESTION # 23
A customer wants to connect a NetApp AFF A700 system to a 40GbE switch. The controllers have a 10/40G
Ethernet card in slot 4 for this purpose. The link comes up fine on node 2,but it will not come up on node 1.
You look at the AutoSupport data for the nodes in question and see the output shown in the exhibit.

What is the cause of the customer's problem?

  • A. The port has an incorrect SFP inserted.
  • B. The incorrect cable is used.
  • C. The ports are configured for 4x10Gbit instead of 40Gbit.
  • D. The cable is plugged in upside down.

Answer: C


NEW QUESTION # 24
You have a customer complaining of long build times from their NetApp ONTAP-based datastores. They
provided you packet traces from the controller and client. Analysis of these traces shows an average service
response time of 1 ms. QoS outputconfirms the same. The client traces are reporting an average of 15 ms in
the same time period.
In this situation, what would be your next step?

  • A. A sync core should be triggered.
  • B. The client that reports high latency should be investigated.
  • C. The cluster is responding slowly and requires further investigation using performance archives.
  • D. The cluster interconnects should be investigated.

Answer: B


NEW QUESTION # 25
A user reports that a colleague saved a file called Test.txt from a UNIX system to a multiprotocol volume.
When opening the file later from a Windows system, it was not the file that they wanted. The file that they
wanted was named TEST~1.TXT.
Which statement explains this behavior?

  • A. UNIX name mapping updated the filename.
  • B. Windows Volume Shadow Copy Service stored an older version of the file.
  • C. Case Insensitivity of SMB clients caused the file to be displayed with a different name.
  • D. A Snapshot copy preserved two versions of the file.

Answer: D


NEW QUESTION # 26
You receive the panic message shown in the exhibit.

In this scenario, which component should you troubleshoot first?

  • A. the PCI card in slot 3
  • B. the CPU
  • C. the memory module in slot 1
  • D. the MetroCluster FC-Vl card in slot 6

Answer: B


NEW QUESTION # 27
You have connection Issues from a Linux host to an AFF A400 FC LUN. You are asked by support to run the
NetApp sanlun command to provide troubleshooting information.
Which NetApp software package must be installed on the host?

  • A. Host Utilities package
  • B. Virtual Storage Console
  • C. Inventory Collect Tool
  • D. SnapDrive for UNIX

Answer: A


NEW QUESTION # 28
You are deploying NetApp ONTAP Select. When trying to add VMware vCenter to the inventory, you receive
the message shown below.
Credential authentication failed for x.x.x.x with: HostConnectionFailed
In this scenario, how would you correct this problem?

  • A. Change the vCenter password.
  • B. Change the gateway address of the ONTAP Select Deploy VM.
  • C. Change the IP address of the ONTAP Select Deploy VM.
  • D. Change the IP address of the vCenter server.

Answer: A


NEW QUESTION # 29
You notice poor performance on your FlexGroup and execute the system node run -node * flexgroup show
command for more Information. You notice the "Urge" column has non-zero values.
In this scenario, which statement is true?

  • A. The aggregate is completely full.
  • B. The constituent volumes are completely full.
  • C. The constituent volumes are out ofInodes.
  • D. The data placement is uneven.

Answer: A


NEW QUESTION # 30

Referring to the exhibit, what do you need to do to return the MetroCluster to a normal state?

  • A. Enter the metroclustor switchback command on Site B.
  • B. Enter the storage failover giveback command on Site A.
  • C. Enter the storage failover giveback command on Site B.
  • D. Enter the metrocluster switchback command on Site A.

Answer: D


NEW QUESTION # 31
When you review performance data for a NetApp ONTAP cluster node, there are back-to-back (B2B) type
consistency points (CPs) found occurring onthe loot aggregate.
In this scenario, how will performance of the client operations on the data aggregates be affected?

  • A. Data aggregates will not be affected by B2B processing on another aggregate.
  • B. During B2B processing, clients will be unable to write data.
  • C. During B2B processing, all I/O to the node is stopped.
  • D. During B2B processing, clients will be unable to read data.

Answer: A


NEW QUESTION # 32
Your customer wants to access a LUN on a FAS 8300 system from a VMware ESXi server through the FC
protocol. They already created a new SVM, volume. LUN, and igroup for this purpose. The customer reports
that the server's FC HBA port Is online, but the LUN does not show up.

Referring to the exhibit, what is the reason for this problem?

  • A. The LUN Is not mapped to the correct SCSI ID.
  • B. The zoning on the FC switches Is Incorrect.
  • C. The esxserver igroup contains incorrect IQNs.
  • D. The FC service has not been configured on the SVM.

Answer: A


NEW QUESTION # 33
......


Network Appliance NS0-593 exam is a certification test designed to validate the skills and knowledge of support engineers who specialize in the NetApp ONTAP platform. NS0-593 exam tests the candidates' ability to configure, troubleshoot, and optimize the ONTAP cluster and storage systems. The NS0-593 exam is designed for professionals who work in data centers, storage administration, and technical support for NetApp products.


Network Appliance NS0-593 certification exam is designed for professionals who want to demonstrate their skills and knowledge in supporting and troubleshooting NetApp ONTAP storage systems. NetApp Certified Support Engineer ONTAP Specialist certification is ideal for those who work in IT support roles and have experience working with NetApp storage solutions. NS0-593 exam covers topics such as installation, configuration, and troubleshooting of NetApp storage systems, as well as data protection, performance optimization, and storage efficiency.

 

NS0-593 Exam Dumps For Certification Exam Preparation: https://www.passreview.com/NS0-593_exam-braindumps.html

Online VALID NS0-593 Exam Dumps File Instantly: https://drive.google.com/open?id=1UXeGGnxnNtCYm7APKtTxHh0sms6JTgmQ