Most UptoDate HP HPE0-S60 Exam Dumps PDF 2023 [Q19-Q40]

Share

Most UptoDate HP HPE0-S60 Exam Dumps PDF 2023

100% Free HPE Technical HPE0-S60 Dumps PDF Demo Cert Guide Cover

NEW QUESTION 19
Match HPE SimpliVity team with the definition.

Answer:

Explanation:

 

NEW QUESTION 20
You need to setup HPE Synergy frames after hardware components are discovered within HPE OneView.
Put the steps to achieve this goal into the coned order in the answer area on the right.

Answer:

Explanation:

1 - Create a logical interconnect group with uplink sets.
2 - Create a logical enciosure.
3 - Create an enciosure group.
4 - Create server profile templates and server profiles.
5 - Define all required networks.

 

NEW QUESTION 21
After HPE Superdome Flex deployment and nPar setup, you need to verify health status of HPE Superdome Flex components.
Put the steps on the left into the coned order on the right to perform this task.

Answer:

Explanation:

 

NEW QUESTION 22
An HPE Synergy customer needs to prevent a timeout and loss of communication during an external switch firmware upgrade.
Click the parameter that the customer should configure within an uplink set to meet this requirement

Answer:

Explanation:

 

NEW QUESTION 23
Your customer plans to deploy a VMware ESXi with HPE Synergy platform. They also plan a vSAN deployment leveraging HPE D3940 Storage Modules and SSD drives The customer requested the following components:
- HPE Synergy frame with ten HPE Synergy 480 Gen10 Plus compute modules
- Two HPE Virtual Connect SE 100Gb F32 Modules for Synergy
- An appropriate number of vSAN Standard licenses for each compute node
- One HPE O3940 Storage Module with 40 SSDs - All required cables and options Which statement about this request is true?

  • A. vSphere licenses should be added, as vSAN licenses do not replace vSphere licenses
  • B. vSphere Standard licenses should be replaced with Enterprise Plus licenses to enable vSAN
  • C. 20 SSD drives should be removed from this setup, as D3940 supports only 20 SSD or SAS drives.
  • D. One HPE Virtual Connect SE 100Gb F32 Module for Synergy should be replaced with 50GD/S ILM

Answer: B

 

NEW QUESTION 24
Your customer plans to setup an HPE Synergy solution based on SY480 Gen10 compute nodes with the following connectivity options - SAS connectivity installed in the first fabric - FC connectivity Installed In the second fabric - Ethernet connectivity installed in the third fabric.
Which statement regarding this setup is true?

  • A. Each compute node must have at least 768GB of memory installed
  • B. Each interconnect module in each fabric must be properly licensed in HPE OneView
  • C. Interconnect modules that provide SAS connectivity should be moved to the third fabric
  • D. Compute nodes must have a second CPU installed to access the second fabric.

Answer: A

 

NEW QUESTION 25
Your customer plans to manage HPE Primera using HPE Oneview
Which storage management tasks can be completed using HPE OneView for this environment?

  • A. CPG management
  • B. Cache management
  • C. Replication setup
  • D. Volume provisioning

Answer: D

 

NEW QUESTION 26
Your customer has an HPE Synergy platform deployed and managed using HPE OneView. The customer also has HPE Superdome Flex with RMC deployed They plan to deploy a second nPar and HPE Superdome Flex
280 They plan to manage new components using HPE OneView
What must be done to achieve this goal?

  • A. The customer should deploy an HPE OneView appliance for HPE Superdome Flex management
  • B. The customer must add a second Rack Management Controller for HPE Superdome Flex 280
  • C. The customer has to add HPE Superdome Flex to the HPE OneView used to manage HPE Synergy
  • D. The customer must use IL05 to add HPE Superdome Flex systems to HPE OneView

Answer: B

 

NEW QUESTION 27
Your customer has a logical enclosure configured using a angle HPE Synergy frame with the following configuration
- two HPE Virtual Connect SE 100Gb F32 Modules for Synergy
- two HPE Synergy Virtual Connect SE 32Gb FC Modules -12 HPE Synergy 480 Gen10 Plus compute nodes with appropriate mezzanine cards They plan to add a new HPE Synergy frame to an existing logical enclosure with the following configuration
- two HPE Synergy Virtual Connect SE 32Gb FC Modules
- two HPE Synergy 20Gb interconnect Link Modules
- Eight HPE Synergy 480 Gen 10 Plus compute nodes with appropriate mezzanine cards Which statement about the planned configuration change is true?

  • A. A license for an extended logical enclosure must be added to HPE OneView through GUI
  • B. The two HPE Synergy 20Gb interconnect Link Modules must be replace with the 50Gb option
  • C. The HPE Synergy virtual Connect SE 32Gb FC Modules from both frames should be stacked
  • D. Four compute modules must be moved to the second frame to balance the configuration

Answer: C

 

NEW QUESTION 28
After deploying HPE Superdome Flex 280 you need to check Core Analysis Engine (CAE) Log.
Click the appropriate section in the HPE Superdome Flex 280 management interface that will allow you to complete this task.

Answer:

Explanation:

 

NEW QUESTION 29
Your customer has me following HPE Synergy setup
- Three frames fully populated with HPE Synergy 480 Gen10 Plus modules and 25Gb/s downlink speed formulating a single logical enclosure
- Two HPE Virtual Connect SE 100Gb F32 Module for Synergy
- Four HPE Synergy 50Gb interconnect Link Module
- Six HPE Synergy Virtual Connect SE 32Gb FC Modules
The customer needs to add a frame.
Which statement about the expansion of this setup is true?

  • A. The additional frame cannot have 12Gb SAS connection modules installed
  • B. The additional frame must have HPE Virtual Connect FC modules installed
  • C. The customer can grow the existing logical enclosure up to 5 frames
  • D. The customer has to create a new logical enclosure for the additional frame

Answer: D

 

NEW QUESTION 30
Which statement about an HPE Oneview support dump is true?

  • A. Support dump is a binary file that can be opened only in a dedicated application
  • B. Support dump can be created if HPE Virtual Connect modules are installed in the frame
  • C. Preview support dump is available only when creating an appliance support dump
  • D. Appliance support dump by default contains a logical enclosure support dump

Answer: A

 

NEW QUESTION 31
You configured a vVoI datastore using HPE Storage integration Pack for VMware vCenter.
Which storage object should you check using SSMC to verify whether vVol datastore is configured property?

  • A. Storage Container
  • B. Virtual Volume Set
  • C. virtual Volume
  • D. App Volume Set

Answer: B

 

NEW QUESTION 32
Which statement about login redistribution is true?

  • A. Login redistribution is available only If HPE Primera or HPE Alletra is connected directly to the HPE Synergy frame
  • B. Login redistribution is supported only on the HPE Synergy Virtual Connect SE 32Gb FC Modules
  • C. Login redistribution is used for login balancing when they are not distributed evenly over the FC links
  • D. Login redistribution is a licensed feature and the number of licenses required depends on the number of active ports

Answer: B

 

NEW QUESTION 33
Refer to the exhibit.

Which statement about this logical JBOD is true?

  • A. This logical JBOD can be connected to multiple systems to formulate a snared datastore.
  • B. After deleting this logical JBOD drives will he blocked for 12h m case this JBOD must be re-created
  • C. After deleting this logical JBOD, its drives w not be available until a clean-up procedure 6 done
  • D. This logical JBOD can be presented to the compute nodes in a different frame.

Answer: C

 

NEW QUESTION 34
Click the drop-down menu that will allow you to define the location of the master modules within the logical interconnect group.

Answer:

Explanation:

 

NEW QUESTION 35
Your customer plans to deploy ESXi systems to HPE Synergy and HPE ProLiant servers using HPE OneView for VMware vCenter Server.
Which statement about HPE OneView for VMware vCenter Server functionality is true for this environment?

  • A. Only systems managed using HPE Oneview can use HPE Oneview for VMware vCenter Server functionalities
  • B. Individual systems can be added to HPE OneView for VMware vCenter Server through an ILO management processor
  • C. HPE ProLiant servers need an HPE OneView for VMware vCenter Server license for full functionality
  • D. HPE Synergy requires HPE Composer 2 for full functionality of HPE OneView for VMware vCenter Server

Answer: C

 

NEW QUESTION 36
Your customer plans to deploy HPE Superdome Flex and configure two nPars, each based on two chassis Which components must be included in the proposal to meet the customer's needs?

  • A. HPE Superdome Flex Grid licenses enabling connectivity between chassis
  • B. At least Tour HPE Persistent Memory DIMMs per nPar
  • C. One base chassis and three expansion chassis with licenses
  • D. Rack Management Controller for nPar management

Answer: C

 

NEW QUESTION 37
Match each HPE OneView network type with its definition.

Answer:

Explanation:

 

NEW QUESTION 38
Match HPE Superdome Flex system with its specific feature.

Answer:

Explanation:

 

NEW QUESTION 39
A logical interconnect group can span on multiple HPE Synergy frames for which interconnect type?

  • A. Brocade 32GB Fibre Channel Switch Module for HPE Synergy
  • B. HPE virtual Connect SE 32 Gb FC Module for Synergy
  • C. HPE Synergy 12 Gb SAS Connection Module
  • D. HPE Virtual Connect SE 100 Gb F32 Module tor Synergy

Answer: D

 

NEW QUESTION 40
......

Updated HP HPE0-S60 Dumps – PDF & Online Engine: https://www.passreview.com/HPE0-S60_exam-braindumps.html

PDF Exam Material 2023 Realistic HPE0-S60 Dumps Questions: https://drive.google.com/open?id=1jY8AE0sSIhvUMEgCUB8Y7EB7mJMY8bTR