2025 New Training Course D-PVM-DS-23 Tutorial Preparation Guide [Q58-Q74]

Share

2025 New Training Course D-PVM-DS-23 Tutorial Preparation Guide

Dumps of D-PVM-DS-23 Cover all the requirements of the Real Exam

NEW QUESTION # 58
A storage administrator uses Unisphere for PowerMax to provision new storage from a VMAX All Flash array.
Which Workload Type is recommended for a combination of small and large block I/O workloads?

  • A. None
  • B. Optimized
  • C. DSS
  • D. OLTP

Answer: B


NEW QUESTION # 59
A PowerMax Storage Group has Host I/O limits set at 10000 IOPS. The Port Group contains four ports across different directors. The Dynamic Distribution is set to OnFailure.
What is the maximum IOPS the Storage Group can achieve in the event a switch port being used by one of the director ports fails but the director remains online?

  • A. 0
  • B. 1
  • C. 2
  • D. 3

Answer: A


NEW QUESTION # 60
Which SRDF/A resiliency feature allows sessions to remain active during transient link outages?

  • A. Group-Level Write Pacing
  • B. Recovery After Link Loss
  • C. Transmit Idle
  • D. Failback

Answer: B


NEW QUESTION # 61
A storage architect is designing a PowerMax solution. The architect must customize the maximum SRDF/A cache usage.
Which system view can the architect use to meet this requirement?

  • A. Data Protection
  • B. System Properties
  • C. Performance
  • D. System Settings

Answer: D


NEW QUESTION # 62
A storage architect is designing a PowerMax solution. The architect must ensure that the Unisphere server is not directly connected to the arrays.
Which type of Unisphere for PowerMax deployment will achieve the design requirements?

  • A. Local Configuration
  • B. eManagement
  • C. CloudIQ
  • D. Remote Configuration

Answer: D


NEW QUESTION # 63
What is the maximum number of front-end ports that can be configured on a PowerMax 8000?

  • A. 0
  • B. 1
  • C. 2
  • D. 3

Answer: D


NEW QUESTION # 64
What action is required on a PowerMax thin device before it can be deleted?

  • A. Set to Write Disable
  • B. Unmap from front-end ports
  • C. Set to Not Ready
  • D. Remove from Storage Group

Answer: D


NEW QUESTION # 65
The Output file of a linux host collection utility does not match the BCSD parser format. what could be the reason?

  • A. BSCD is incorrectly configured
  • B. OS patches are not up to date
  • C. Perform is not up to date
  • D. Incorrect LUNs specified

Answer: A


NEW QUESTION # 66
What types of files are supported for import into Sizer?

  • A. BTP, DCF, and configuration files only
  • B. BTP, DCF, CSV, and configuration files
  • C. TTP, DCF, CSV, and configuration files
  • D. TTP, CSV, and configuration files only

Answer: B


NEW QUESTION # 67
What is a characteristic of a PowerMax Open Replicator control device?

  • A. Can be involved in a TimeFinder session
  • B. Can be R2 in an SRDF configuration
  • C. Cannot be R1 in an SRDF configuration
  • D. Cannot be involved in a TimeFinder session

Answer: D


NEW QUESTION # 68
A storage architect is looking for best practices to expand an existing two-Brick PowerMax 8000. They are planning to expand the PowerMax configuration to a four-Brick model for better performance.
What is a consideration?

  • A. The maximum number of drives is 96
  • B. Only three different RAID configurations are supported
  • C. Cache size of the fourth Brick can be either 1 TB or 2 TB
  • D. All Bricks must contain at least 512 GB of cache each

Answer: C


NEW QUESTION # 69
A storage administrator has mounted a snapshot of an existing datastore to the ESXi server and decided to keep its existing signature.
What action is prevented by keeping the existing signature?

  • A. Increasing the datastore size
  • B. Modifying the datastore configuration
  • C. Replicating the datastore
  • D. Restoring the datastore

Answer: D


NEW QUESTION # 70
A customer is planning to implement SRDF/Metro, using the default Device Bias method.
What is a consideration?

  • A. There is no way to make the R2 device available to the host.
  • B. Bias cannot be changes in the SRDF/Metro group.
  • C. The state of the device pair is ActiveActive.
  • D. This setting applies to all SRDF groups in both arrays.

Answer: C


NEW QUESTION # 71
Which product allows for local protection for Z Systems?

  • A. RecoverPoint
  • B. AppSync
  • C. TimeFinder SnapVX
  • D. PowerProtect

Answer: C


NEW QUESTION # 72
A storage architect wants to estimate how much additional workload a VMAX All Flash running Enginuity 5876 can handle.
Which FAST component can be used to display application performance metrics on this storage system?

  • A. Unisphere server installed on an open systems host
  • B. Storage Groups associated with a Service Level
  • C. FAST does not have this option on a VMAX All Flash
  • D. Unisphere for PowerMax Workload Planner

Answer: D


NEW QUESTION # 73
Data is being migrated from a VNX to a PowerMax using Open Replicator. The Pace Value is 0 with a Celling of 10%. Copies are taking a very long time to complete.
What could be done to resolve this issue?

  • A. Set Pace to 10; set Ceiling to 100%
  • B. Leave Pace as-is; set Ceiling to 100%
  • C. Set Pace to 10; set Ceiling to 0%
  • D. Leave Pace as-is; set Ceiling to None

Answer: B


NEW QUESTION # 74
......

Sample Questions of D-PVM-DS-23 Dumps With 100% Exam Passing Guarantee: https://www.passreview.com/D-PVM-DS-23_exam-braindumps.html

Correct Practice Tests of D-PVM-DS-23 Dumps with Practice Exam: https://drive.google.com/open?id=1KWuU3l4Erngxb5eNJx7cwyEXigh4JdR0